1. Channel A leads Channel B for clockwise rotation when viewed from shaft end.
2. Symmetry is the ratio of the ON time to the OFF time of the output signal Optimally
50-50
3. Quadrature is specified by the displacement of Channels A and B in electrical degrees.
4. Zero Reference, when ordered is approximately centered on positive - going edge of Channel B and is 180∞ ± 90∞ (electrical) wide.
5. Complementary signals (A, B, Z) are available as options (standard with line drivers.)